Skip to main content

Log fuel fills and pumpouts

Use Trip Log to keep fuel-fill and pumpout records, including service between trips. You can backdate an entry, review nearby historical tank readings, and correct saved details later.

Before you start​

You need administrator access to create, edit, or delete entries, and the vessel must run a BoatKit software version that supports fuel-fill and pumpout logging. Viewers can inspect saved entries and recorded gauges.

Configured tanks, sensors, and live readings are optional. You can save a service record without them. Historical gauge comparisons require recorded tank sensor history around the service time.

Record a fuel fill or pumpout​

  1. Open Trip Log and choose + New.
  2. Choose Track Fuel Fill or Track Pumpout.
  3. Set Date and time to when the service happened. You can enter a past date and time. The field uses the viewing device's local time zone, including when you connect remotely.
  4. For a fuel fill, choose Diesel, Gasoline, or Other under Fuel type. Enter Quantity added or Quantity removed in the volume units shown, or leave it blank if the amount is unknown.
  5. Under Tanks (optional), select the tanks involved if you want to identify them. Fuel fills offer enabled fuel tanks; pumpouts offer enabled black-water and gray-water tanks. Select Filled to full or Emptied completely if that describes the service.
  6. Optionally enter Total cost (optional), Marina or location, and Notes. If you enter a cost, also enter a three-letter Currency code, such as USD.
  7. Choose Save fuel fill or Save pumpout.

Confirm it is working​

In Trip Log, choose Fuel fills or Pumpouts. Find your saved entry and check its date, time, and details. Use Previous and Next when the history spans multiple pages. Open the entry's card to review all fields and Recorded gauge values.

These filters show history for the whole vessel, including entries made between trips. An entry also appears in any trip whose time range covers its recorded time. In a trip timeline, choose View details to open it.

Editing or deleting a trip does not delete the service entry.

Trip Log opens in All, showing trips, fuel fills, and pumpouts together, newest first. The icon at the left identifies the entry type. Use Trips, Fuel fills, or Pumpouts to narrow the list; Show more loads older entries in All.

Open a trip to inspect its event timeline. Engine-start and engine-stop rows include each engine's hour meter when nearby recorded sensor history is available, including rows that combine multiple engines. These are historical readings; missing or expired history leaves the meter unavailable.

When Include earlier anchor-watch changes is enabled in Settings > Trips, turning off anchor watch records an event and waits for an engine or speed start to confirm a trip. If confirmation follows within two hours, the trip starts at the earlier anchor event. Without confirmation in that window, no standalone trip is created. Re-enabling anchor watch cancels the earlier precursor. Manual trips keep their chosen time range.

Settings > Trips > Auto stop idle duration keeps a trip open through brief stops and engine restarts. The default is 30 minutes after all selected engine and speed criteria become idle. Activity resuming within that window continues the same trip and resets the idle timer. Once the full idle window passes, the trip closes with its end time at the start of that idle period. A manual stop ends the trip immediately. If restarts still create separate trips, check the saved idle duration; an existing custom value is retained.

Understand recorded gauge values​

BoatKit looks for historical tank-level and remaining-volume readings around the entry time:

  • Level before and Volume before use the earliest valid sample within the preceding hour, aiming for one hour before the entry.
  • Level after and Volume after use the latest valid sample strictly after the entry, within the following hour, aiming for one hour after it.

This compares readings near the ends of the window, rather than two readings just seconds apart while service is still underway. If an entry is less than an hour old, the after value uses the latest available sample inside the window; Refresh readings can pick up later samples.

Each measurement shows its own sample timestamp. Check those timestamps when comparing values: the measurements may come from different moments, may be identical, or may still reflect a settling tank reading.

BoatKit does not infer the quantity added or removed from the difference between readings. Purchased fuel is recorded separately from engine fuel consumption.

Changing Date and time starts another history lookup. Choose Refresh readings to look again, including for samples recorded after you saved the entry.

Gauge readings are derived from raw sensor history—the original recorded samples—and are not permanently attached to the service entry. Missing, invalid, expired, or outside-window samples are not replaced with current telemetry.

Correct or delete an entry​

  1. Open the saved entry from its Fuel fills or Pumpouts history card, or choose View details in a trip timeline.
  2. Edit the fields and choose Save changes. Changing the recorded time also changes which trip time ranges contain the entry and which historical readings BoatKit looks up.

To remove an entry, choose Delete entry, review the Delete log entry confirmation, and choose Delete. This deletes the service entry from the vessel log.

Offline use and backups​

When connected locally to the vessel's running BoatKit, you can create, review, edit, and delete entries without Internet access. You can also use ordinary BoatKit Cloud remote access when connected to the vessel through BoatKit Cloud.

Vessel-history backups include service entries and later corrections and deletions. Incremental backups select changes by when an entry was updated, so a newly saved backdated entry can be included. Historical gauges depend separately on retained or restored raw sensor history.

If something is missing​

  • No creation or editing controls: Check that you have administrator access. If Track Fuel Fill, Track Pumpout, or the history filters are missing, check that the vessel's BoatKit software supports them and update it if needed.
  • An entry is missing from a trip: Find it under Fuel fills or Pumpouts, then compare its recorded date and time with the trip's time range.
  • An expected tank is missing: Check that it is enabled and has the appropriate tank type: fuel for fills, or black water or gray water for pumpouts.
  • A gauge says “No recorded reading”: Check the entry's date and time and any available sample timestamps. BoatKit needs a valid sample within one hour on the relevant side of the entry time. For recent service, try Refresh readings after more samples have been recorded. For older entries, check whether raw sensor history was retained or restored.